Web徐 琛,何 玮,雷 强,徐春艳,刘志辉,蒋 婧,*(1.生态环境部 核与辐射安全中心,北京 100082;2.福清核电有限公司,福建 福清 WebJun 8, 2014 · These results confirmed that OptiPhase HiSafe 2 is not suitable for strong electrolytes and very high and very low pH values, as is stated by its producer. Acetone as …
Optiphase hisafe
Did you know?
WebIn the second method, the precipitate was dissolved with 0.2 M ethylene-diamine-tetra-acetic-acid solution (9 ml) and 11 ml of scintillation solution (Optiphase Hisafe 3) was added to the vial, forming an aqueous and an organic phase. Webtail (Optiphase 'Hisafe') was added, and the radio activity was measured using a Pharmacia-LKB 1409 liquid scintillation counter. Photosynthetic dissolved organic carbon. Photosyn thetic dissolved organic carbon was measured using the acid bubbling method (Wood & Vaalen 1990, Jiao & Wang 1994), with slight modifications: 5 ml filtrate
WebScintillator (OptiPhase ‘HiSafe’ 3, 10 ml) was added for scintillation counting. The production of [3H]-cyclic AMP from cellular [ H]-ATP in the presence of a phosphodiesterase inhibitor (i.e., adenylyl cyclase activity) was estimated as the ratio of radiolabelled cyclic AMP to total AXP (i.e., adenine, cyclic AMP, ADP WebJun 1, 2015 · Optimal PSA dependence on radionuclide ( 241 Am and 90 Sr) activity concentration, obtained with OptiPhase HiSafe 3 cocktail. Table 1. Working PSA …
WebOptiPhase HiSafe 2 is a general purpose liquid scintillation cocktail. It combines very high counting efficiency with moderate to high sample holding capacity for a wide range of aqueous and non-aqueous solutes. Optiphase Hisafe 2, 5L PerkinElmer, Inc. The supplier does not provide quotations for this particular product through SelectScience. WebOptiPhase HiSafe 3 is a liquid scintillation cocktail capable of handling a broad range of solutes, thus making it ideal for a variety of scintillation applications. It is recommended for use with T-tray samples in Betaplate. It combines good counting efficiency with a very high level of sample acceptance, particularly for high ionic strength ...
WebJun 1, 2008 · The observed effect of quenching on the counting efficiency for two representative cases (OptiPhase HiSafe-3 and Ready-Gel) is shown in Fig. 1.The quench resistance functions and calculated values for quench half-volume V 1/2 for the different cocktails and for 3 H and 14 C spiked samples are shown in Table 2.The average value of …
WebMar 3, 2015 · OptiPhase HiSafe 3 is the preferred liquid scintillator for proton dosimetry because its stopping power and density are more water-equivalent than those of BC-531. Diluting OptiPhase with water achieves a slight improvement with an acceptable loss in scintillation output. However, dilution is not necessary because the linear stopping power … ct 免费WebUltimaGoldTM AB and OptiphaseTrisafe are two liquid scintillators made by Perkin Elmer and EG & G Company respectively. Both are commercially promoted as scintillation detectors for α and β... easlan management co. incWeb邵延江,王 波,周 舵,陈 曦,方 升,徐毓炜,许强伟,刘 晨,包良进,龙浩骑,鲜 亮 (1.中国原子能科学研究院 退役治理工程技术中心,北京 102413;2.中国原子能科学研究院 放射化学研究所,北京 102413;3.国家知识产权局专利局专利审查协作北京中心,北京 100081) easl cpg alf. j hepatol 2017 66:1047–81WebJan 28, 2016 · In the case of 63 Ni, the most usual scintillation cocktail used is Optiphase Hisafe 3 and, as such, in the present study, it was mixed with different volumes of 2 M HNO 3. The best efficiency was obtained using the combination of 4 mL of sample and 16 mL of Optiphase Hisafe 3, at 55 ± 5 %, which is similar to the values reported in the ... easlecar.irWebOptiPhase HiSafe 3 OptiPhase HiSafe 3 is a liquid scintillator that handles a broad range of solutes. Used for a variety of scintillation applications, it combines good counting … easl corkWebApr 8, 2024 · Radioactivity was then measured in the supernatant in 4 mL scintillation cocktail Optiphase Hisafe 2 (PerkinElmer) by LKB Rackbeta counter (LKB Instrument). Corrections were made for non-specific binding. Relative binding affinity (RBA) was calculated as the ratio of FLTX2 and TX IC 50 values obtained from dose-response curves. ct 列WebOct 1, 2015 · One of the possible reasons for the difference between the two kinds of cocktail may be that there are some chelating ligands for trivalent metallic ions in OptiPhase Hisafe 3, which will decrease the possibility of adsorption. eas latein